This method can be used to assess the flame behavior of gloves.
A defined flame from a burner is brought into contact with the lower edge of the glove for a defined time, with the glove suspended vertically from the wrist. After the burner flame has stopped, the flame persistence and residual incandescence times are measured.
Type: Physical and mechanical test
Standard: EN 407 § 4.5.2
Product: Gloves
Criterias: PEE / Thermal risk