EN
This test verifies impact resistance after conditioning in temperatures and chemical.
For Class I and II non-metallic tips, an impact test is carried out after various temperature conditions and contact with chemical.
When non-metallic toecaps are subject to each single one of the treatments according to ISO 20344:2021 , 5.6.2, the clearance under the toecap, at the moment of impact, shall not be less than the appropriate value . In addition, the non-metallic toecap shall not develop delamination or sharp edges or any cracks passing through the material (i.e. through which light can be seen). During the assessment of the non-metallic toecap designed with perforations the criteria whether light can be seen shall not be applied to the perforation.
Type: Physical and mechanical test
Standards: EN ISO 20344 §5.6.2 / EN ISO 20345 §5.3.2.5
Product: Footwear
Criterias: Mechanical risk / PEE
Component: Whole shoe
Last modified on 2025-05-13