Toecaps corrosion resistance

 

Objective

There should be no more than 3 corrosion points on the metal toecaps, none of which should be more than 2 mm long.

 

Principle

The toecaps is placed in contact with a sodium chloride solution in accordance with EN ISO 22568-1 §5.5 for 7 days.
The number of corrosion zones and the greatest length of each zone are then recorded.

 

Type: Physical and mechanical test
Standards: EN ISO 20344 §5.6.2 / EN ISO 20345 §5.3.2.4
Product: Footwear
Criterias: Mechanical risk / PEE
Component: Whole shoe