This test verifies the impact resistance of toe protectors.
A 20 kg steel striker with a hardness of 60 HRC and a 90° wedge angle is dropped on the protective tip. This represents a shock of 200 joules, and the residual height is measured to leave enough room for the toe.
Type: Physical and mechanical test
Standards: EN ISO 20344 §5.4 / EN ISO 20345 §5.3.2.6
Product: Footwear
Criterias: Mechanical risk / PEE
Component: Whole shoe